8.7 TROUBLESHOOTING - ERROR 01A1
CHAPTER 8: TROUBLESHOOTING
ERROR CODE 01A1
1) SYMPTOM:
01A1 – Incline calibration error. It occurs when the calibration time is too long or the calibration distance is too short.
2) SOLUTION:
1) Follow the instructions in Section 3.5 to run Auto Calibration (Figure B).
2) Disconnect the incline tube from the incline frame (Figure A), then turn on the power.
- If the console still shows 01A1, replace the incline motor.
- If the console does not show 01A1, follow incline motor installation procedure in Section 9.13 to re-attach the incline motor.
3) Replace the LCB.