110 V UNITS
All Matrix 3x, 5x, 7xe and 7xi 110 V Steppers require the use of
a 100-125 V, 60 Hz and a 15 A “Dedicated Circuit”, with a non-
looped (isolated) neutral/ground for power. This outlet should be
a NEMA 5-15R and have the same configuration as the plug. No
adapter should be used with this product. Steppers can be daisy-
chained together with up to 4 units per 15 A dedicated circuit.
Matrix daisy-chain cord adapters are sold separately.
220 V UNITS
All Matrix 3x, 5x, 7xe and 7xi 220 V Steppers require the use of
a 216-250 V, 50 Hz and a 15 A “Dedicated Circuit”, with a non-
looped (isolated) neutral/ground for power. This outlet should be
a NEMA 6-15R and have the same configuration as the plug. No
adapter should be used with this product. These Steppers can
be daisy-chained together with up to 4 units per dedicated 15 A
circuit. Matrix daisy-chain cord adapters are sold separately.
GROUNDING INSTRUCTIONS
The unit must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current
to reduce the risk of electric shock. The unit is equipped with a
cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that
is properly installed and grounded in accordance with all local
codes and ordinances. If the user does not follow these grounding
instructions, the user could void the Matrix limited warranty.
ADDITIONAL ELECTRICAL INFO
In addition to the dedicated circuit requirement, the proper
gauge wire must be used from the circuit breaker box, to
each outlet that will have the maximum number of units
running off of it. If the distance from the circuit breaker box
to each outlet, is 100 ft (30.5 m) or less, then 12 gauge
wire should be used. For distances greater than 100 ft
(30.5 m) from the circuit breaker box to the outlet, a 10
gauge wire should be used.
ENERGY SAVING / LOW-POWER MODE
All units are configured with the ability to enter into an
energy saving / low-power mode when the unit has not
been in use for a specified period of time. Additional time
may be required to fully reactivate this unit once it has
entered the low-power mode. This energy saving feature
may be enabled or disabled from within the ‘Manager
Mode’ or ‘Engineering Mode.’
ADD-ON PCTV (3X AND 5X)
A 15 A or 20 A “Dedicated Circuit” with a non-looped
(isolated) neutral/ground is required. Each PCTV requires
at least 1.2 A of current. No more than 12 PCTVs should
be used for each 15 A circuit and no more than 16 PCTVs
should be used for each 20 A circuit. The power outlet
should have the same configuration as the plug. No
adapter should be used with this product. An RG6 coaxial
cable with ‘F Type’ compression fittings will need to be
connected between the video source and each add-on
PCTV unit.
ADD-ON DIGITAL TV (3X AND 5X)
Additional power requirements are not needed for the
add-on digital TV. An RG6 coaxial cable with ‘F Type’
compression fittings will need to be connected between
the video source and each add-on digital TV unit.
220 NEMA 6-15P
PLUG
110 NEMA 5-15P
PLUG
North American power cord
plugs shown. Depending on
your country, the plug type
may vary.